Modules

DB14 Pulse count/ Digital input module (up to 5 VDC) - 4 channels

DB14 Pulse count/ Digital input module (up to 5 VDC) - 4 channels
Product family: Modules (change)
Region:
Available module ports:
Choose a module
Input 1
Input 2
Input 3
Input 4
  • Compatible with any N series gateway, sensor/ control device or data logger with expansion ports
  • Requires one (1) expansion port
  • Pulsecount/ Digital sensor (0-5 VDC)- 4 channels
  • External sensors include wet/dry flow meters, leak detection, door position (open/ close), contact relay monitoring among numerous other sensors with pulse, digital I/O or VDC outputs.
  • Terminal block for connections
  • Monitoring gas and water usage (flowmeters), digital outputs from industrial or HVAC controllers, True power with Wattnode meters
Ships in 1-2 weeks
Price¥7,700 (excl. tax)
Add to Quote
Description
Specifications
Support

The expansion module model DB14 accepts inputs from external sensors, flowmeters and True Power meters via a 5 position terminal block. Inputs such as pulse-count and 0-3.3VDC can be used. External sensors include wet/dry flow meters, leak detection , door position (open/ close) , contact relay monitoring among numerous other external sensors with pulse or digital outputs. The multi-channel unit can handle up to 4 different inputs simultaneously. The module is ideal for monitoring gas and water flowmeters, as well as general purpose monitoring digital outputs from other equipment such as industrial or HVAC controllers. The easy access terminal blocks with screw down clamps provide secure connections for open wires. The DB14 module requires a single expansion port on the base device. Our DataRecorder and configuration utility software can be programmed to display the proper measurement units for each individual sensor input. In addition, remote email or text(SMS) alarm notifications can also be enabled with our HaloCloud service.

Our N-series monitoring, control, datalogging systems and standalone devices provide a flexible, scaleable and customized solution to meet any of your application requirements. From complete multipoint wired and/or wireless cloud base systems to individual data loggers, our new design platform, features and modular sensor/ control options are the perfect choice for your needs. All of our systems include Paragon Robotics suite of customizable software tools including monitoring dashboards, datalogging and charting, export/ import capabilities and individual alarm setpoint configurations and notifications. With a network internet connection to the system or individual data loggers, any device is remotely accessible via the cloud from any location.

What's included

  • This device

Features

  • Compatibility with N series gateways, sensor and control devices and data loggers
  • DB Modules utilize 1 expansion port on base unit
  • Broad range of built in sensors, controls and compatibility with external probes, sensors and instrumentation
  • Modular design allows fo custom solutions with mixed sensors and controls on same base unit
  • Temperature modules for Thermistor, RTD and Thermocouple probes
  • Monitor flowmeters with pulsecount outputs
  • Energy efficiency modules for CT clamps, Three phase true power, sub power and Wattnode devices
  • Automation capabilities with controls signals - digital I/O, analog I/O, relays and power supplies
  • Bacnet and Modbus integration with N series gateway based system

Applications

  • Energy management, auditing, monitoring, analytics
  • HVAC systems
  • Energy efficiency and savings systems
  • Buildings and facilities monitoring
  • Refrigeration storage systems
  • Life sciences
  • Hospitals - clean and ante rooms
  • Environmental data acquisition and studies
  • Product storage and warehouse
  • Museums monitoring
  • Medical /pharmaceutical
  • Industrial process monitoring/ automation

All of our systems include Paragon Robotics suite of customizable software tools including monitoring dashboards, datalogging and charting, export/ import capabilities and individual alarm setpoint configurations and notifications. With a network internet connection to the system or individual data loggers, any device is remotely accessible via the cloud from any location.

DB14 0-5V digital in
Required Interface Package
N series gateway, sensor/ control device or data logger with expansion ports
Test
Test
Required interface package
N series gateway, sensor/ control device or data logger with expansion ports
Measurement channels
Pulsecount/ Digital, four channel
Sensor
Pulsecount, Flowmeters, True Power
Measurement range
External sensor range
Units
Programmable for external sensor units
Sample rate
10 Hz to 32 Hrs
Sensor response Time (90%)
0.1s
Resolution
0.8mV
Calibrated accuracy
±2mV
Temporary sensor memory
Up to 2 million data points
Long -term memory (using Gateway)
Up to several million data points
Enclosure material
Ruggedized polycarbonate plastic
Upgradable firmware
Yes
Indoor/outdoor
Indoor
Operating environment
-40~+85°C (-40~+185°F); 0~95%RH non-condensing using optional lithium batteries (supplied alkaline batteries -15~+55°C)
Dimensions
70x45x22 (mm) (2.76 x 1.77 x 1.73)
Weight
14g.
Approvals
US(FCC), CA(IC)
Warranty
One (1) year parts and service
DB module manualPDF manual
Contact technical supportEmail or phone